				@@ -634,10 +634,25 @@ func (c *CheckAreaMgr) CheckIedFcda() error { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			iedlst := filterAreaIeds(ied_type, vol, s1) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			for _, ied := range iedlst { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 				iedname := tools.IsEmpty(ied["ied_name"]) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+				iedObj := scdNodeMgr.GetIed(scdXmlObj, fmt.Sprintf("%d", c.ScdId), iedname) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+				iedObjDesc := "" 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+				if iedObj != nil { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+					iedObjDesc = iedObj.Desc 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+				} else { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+					logger.Logger.Error(fmt.Sprintf("信号接收装置%s未找到!", iedname)) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+				} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 				extreflist := getIedExtRefs(iedname) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 				for outiedname, refrow := range outiedlist { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-					iedObj := scdNodeMgr.GetIed(scdXmlObj, fmt.Sprintf("%d", c.ScdId), iedname) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 					outIedObj := scdNodeMgr.GetIed(scdXmlObj, fmt.Sprintf("%d", c.ScdId), outiedname) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+					outIedObjDesc := "" 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+					if outIedObj == nil { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+						logger.Logger.Error(fmt.Sprintf("信号输出装置%s未找到!", outiedname)) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+					} else { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+						outIedObjDesc = outIedObj.Desc 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+					} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+					if iedObj == nil && outIedObj == nil { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+						continue 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+					} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 					outiedFcdaList := getIedFcdas(outiedname) //输入装置的信号输出端子 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 					//检查是否有错误和缺失的端子 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 					hasYaoXinFunc := false //是否具备遥信功能 
			 | 
		
	
	
		
			
				| 
					
				 | 
			
			
				@@ -666,17 +681,12 @@ func (c *CheckAreaMgr) CheckIedFcda() error { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 							} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 						} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 						if !funcExist { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-							iedObj := scdNodeMgr.GetIed(scdXmlObj, fmt.Sprintf("%d", c.ScdId), iedname) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-							outIedObj := scdNodeMgr.GetIed(scdXmlObj, fmt.Sprintf("%d", c.ScdId), outiedname) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-							parse_result := "" 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-							if !funcExist { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-								parse_result = fmt.Sprintf("间隔%s的装置%s缺失端子%s", area_name, iedname, extref_name) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-							} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+							parse_result := fmt.Sprintf("间隔%s的装置%s缺失端子%s", area_name, iedname, extref_name) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 							re := map[string]interface{}{"scdid": c.ScdId, "lineno": 0, "ruleid": area_ruleid, "nodeid": 0, "parse_result": parse_result, 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 								"ied_name":      iedname, 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-								"ied_desc":      iedObj.Desc, 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+								"ied_desc":      iedObjDesc, 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 								"out_ied_name":  outiedname, 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-								"out_ied_desc":  outIedObj.Desc, 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+								"out_ied_desc":  outIedObjDesc, 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 								"fcda_desc":     extref_name, 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 								"fcda_addr":     "", 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 								"out_fcda_desc": fcda_name, 
			 | 
		
	
	
		
			
				| 
					
				 | 
			
			
				@@ -941,27 +951,32 @@ func (c *CheckAreaMgr) pT(modelid int, iedtypes string, ieds map[string]orm.Para 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 		volMap["low"] = volRows[len(volRows)-1]["vol"].(string) //低压电压等级 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 	} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				  
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-	var getIedByDesc = func(iedinfo map[string]orm.Params, desc string) (string, string) { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+	var getIedByDesc = func(iedinfo map[string]orm.Params, iedtpye string, desc string) ([]string, []string) { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 		scdParseMgr := new(ScdParse) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 		scdXmlObj, _ := scdParseMgr.GetScdXmlObjectBySCDID(tools.IsEmpty(c.ScdId)) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+		r1 := []string{} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+		r2 := []string{} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 		for vn, row := range iedinfo { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-			v := tools.IsEmpty(row["ied_desc"]) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-			if v == "" { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-				if scdXmlObj == nil { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-					return "", "" 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+			if strings.HasPrefix(vn, iedtpye) { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+				v := tools.IsEmpty(row["ied_desc"]) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+				if v == "" { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+					if scdXmlObj == nil { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+						continue 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+					} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+					scdNode := new(ScdNode) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+					ied := scdNode.GetIed(scdXmlObj, "", vn) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+					if ied == nil { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+						continue 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+					} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+					v = ied.Desc 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 				} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-				scdNode := new(ScdNode) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-				ied := scdNode.GetIed(scdXmlObj, "", vn) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-				if ied == nil { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-					return "", "" 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+				if strings.Contains(v, desc) { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+					r1 = append(r1, v) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+					r2 = append(r2, vn) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 				} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-				v = ied.Desc 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-			} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-			if strings.Contains(v, desc) { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-				return v, vn 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 		} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-		return "", "" 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+		return r1, r2 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 	} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 	//判断是否将各电压等级的保护装置合并还是分开的间隔 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 	//如果存在高中低压的保护装置,则说明是分开的主变间隔 
			 | 
		
	
	
		
			
				| 
					
				 | 
			
			
				@@ -1001,16 +1016,28 @@ func (c *CheckAreaMgr) pT(modelid int, iedtypes string, ieds map[string]orm.Para 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 		insvalues = append(insvalues, fmt.Sprintf("(%d,%d,'%s','%s','%s')", c.ScdId, newid, inAreaIedName, "P", "T")) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 		//判断间隔是否需要包含差动装置 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 		if strings.Contains(iedtypes, "PT#C") { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-			ieddesc, iedname := getIedByDesc(ieds, "差动") 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-			if strings.Contains(ieddesc, "差动") { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-				insvalues = append(insvalues, fmt.Sprintf("(%d,%d,'%s','%s','%s')", c.ScdId, newid, iedname, "P", "TC")) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+			_, iedname := getIedByDesc(ieds, "PT", "差动") 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+			if len(iedname) > 0 { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+				for _, in := range iedname { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+					tmpIednameParts := scdParseMgr.ParseIedName(in) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+					if tmpIednameParts[6] == iednameParts[6] && tmpIednameParts[7] == iednameParts[7] { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+						insvalues = append(insvalues, fmt.Sprintf("(%d,%d,'%s','%s','%s')", c.ScdId, newid, in, "P", "TC")) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+						break 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+					} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+				} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 		} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 		//判断间隔是否需要包含本体保护装置 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 		if strings.Contains(iedtypes, "PT#0") { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-			ieddesc, iedname := getIedByDesc(ieds, "本体") 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-			if strings.Contains(ieddesc, "本体") { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-				insvalues = append(insvalues, fmt.Sprintf("(%d,%d,'%s','%s','%s')", c.ScdId, newid, iedname, "P", "T0")) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+			_, iedname := getIedByDesc(ieds, "PT", "本体") 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+			if len(iedname) > 0 { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+				for _, in := range iedname { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+					tmpIednameParts := scdParseMgr.ParseIedName(in) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+					if tmpIednameParts[6] == iednameParts[6] && tmpIednameParts[7] == iednameParts[7] { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+						insvalues = append(insvalues, fmt.Sprintf("(%d,%d,'%s','%s','%s')", c.ScdId, newid, in, "P", "T0")) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+						break 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+					} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+				} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 		} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 		//合智一体IMT/MIT,分高中低压 
			 | 
		
	
	
		
			
				| 
					
				 | 
			
			
				@@ -1020,8 +1047,7 @@ func (c *CheckAreaMgr) pT(modelid int, iedtypes string, ieds map[string]orm.Para 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 		for _, r := range h { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			inAreaIedName = tools.IsEmpty(r["ied_name"]) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			tmpIednameParts := scdParseMgr.ParseIedName(inAreaIedName) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-			lastChar := tmpIednameParts[7] 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-			if lastChar == iednameParts[7] { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+			if tmpIednameParts[6] == iednameParts[6] && tmpIednameParts[7] == iednameParts[7] { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 				insvalues = append(insvalues, fmt.Sprintf("(%d,%d,'%s','%s','%s')", c.ScdId, newid, inAreaIedName, "IM", "T")) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 		} 
			 | 
		
	
	
		
			
				| 
					
				 | 
			
			
				@@ -1031,8 +1057,7 @@ func (c *CheckAreaMgr) pT(modelid int, iedtypes string, ieds map[string]orm.Para 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 		for _, r := range h { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			inAreaIedName = tools.IsEmpty(r["ied_name"]) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			tmpIednameParts := scdParseMgr.ParseIedName(inAreaIedName) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-			lastChar := tmpIednameParts[7] 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-			if lastChar == iednameParts[7] { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+			if tmpIednameParts[6] == iednameParts[6] && tmpIednameParts[7] == iednameParts[7] { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 				insvalues = append(insvalues, fmt.Sprintf("(%d,%d,'%s','%s','%s')", c.ScdId, newid, inAreaIedName, "MI", "T")) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 		} 
			 | 
		
	
	
		
			
				| 
					
				 | 
			
			
				@@ -1043,8 +1068,7 @@ func (c *CheckAreaMgr) pT(modelid int, iedtypes string, ieds map[string]orm.Para 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 				//高压侧,AB套必须与PT装置相同 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 				inAreaIedName = tools.IsEmpty(r["ied_name"]) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 				tmpIednameParts := scdParseMgr.ParseIedName(inAreaIedName) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-				lastChar := tmpIednameParts[7] 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-				if lastChar == iednameParts[7] { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+				if tmpIednameParts[6] == iednameParts[6] && tmpIednameParts[7] == iednameParts[7] { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 					insvalues = append(insvalues, fmt.Sprintf("(%d,%d,'%s','%s','%s')", c.ScdId, newid, inAreaIedName, "I", "E")) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 				} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			} 
			 | 
		
	
	
		
			
				| 
					
				 | 
			
			
				@@ -1053,7 +1077,7 @@ func (c *CheckAreaMgr) pT(modelid int, iedtypes string, ieds map[string]orm.Para 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 				inAreaIedName = tools.IsEmpty(r["ied_name"]) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 				tmpIednameParts := scdParseMgr.ParseIedName(inAreaIedName) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 				lastChar := tmpIednameParts[7] 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-				if lastChar == "" || lastChar == iednameParts[7] { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+				if tmpIednameParts[6] == iednameParts[6] && (lastChar == "" || tmpIednameParts[7] == iednameParts[7]) { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 					insvalues = append(insvalues, fmt.Sprintf("(%d,%d,'%s','%s','%s')", c.ScdId, newid, inAreaIedName, "I", "E")) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 				} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			} 
			 | 
		
	
	
		
			
				| 
					
				 | 
			
			
				@@ -1065,11 +1089,23 @@ func (c *CheckAreaMgr) pT(modelid int, iedtypes string, ieds map[string]orm.Para 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 		for _, r := range h { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			inAreaIedName = tools.IsEmpty(r["ied_name"]) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			tmpIednameParts := scdParseMgr.ParseIedName(inAreaIedName) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-			lastChar := tmpIednameParts[7] 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-			if lastChar == iednameParts[7] { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+			if tmpIednameParts[6] == iednameParts[6] && tmpIednameParts[7] == iednameParts[7] { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 				insvalues = append(insvalues, fmt.Sprintf("(%d,%d,'%s','%s','%s')", c.ScdId, newid, inAreaIedName, "M", "T")) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 		} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+		//是否包含本体合并单元 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+		if strings.Contains(iedtypes, "MT#0") { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+			_, iedname := getIedByDesc(ieds, "MT", "本体") 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+			if len(iedname) > 0 { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+				for _, in := range iedname { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+					tmpIednameParts := scdParseMgr.ParseIedName(in) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+					if tmpIednameParts[6] == iednameParts[6] && tmpIednameParts[7] == iednameParts[7] { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+						insvalues = append(insvalues, fmt.Sprintf("(%d,%d,'%s','%s','%s')", c.ScdId, newid, in, "M", "T")) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+						break 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+					} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+				} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+			} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+		} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 		//测控装置CT分高中低压侧,且可能是多套合并单元MT共用,既不分AB套 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 		h, m, l = c.getIedListByVol("CT", ieds, volMap) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 		h = append(h, m...) 
			 | 
		
	
	
		
			
				| 
					
				 | 
			
			
				@@ -1080,10 +1116,23 @@ func (c *CheckAreaMgr) pT(modelid int, iedtypes string, ieds map[string]orm.Para 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			lastChar := tmpIednameParts[7] 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			tmpVol := tmpIednameParts[3] + tmpIednameParts[4] 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			//高中低压电压等级相同的 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-			if (tmpVol == volMap["low"] || tmpVol == volMap["middle"] || tmpVol == volMap["hight"]) && (lastChar == "" || lastChar == iednameParts[7]) { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+			if (tmpVol == volMap["low"] || tmpVol == volMap["middle"] || tmpVol == volMap["hight"]) && tmpIednameParts[6] == iednameParts[6] && (lastChar == "" || lastChar == iednameParts[7]) { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 				insvalues = append(insvalues, fmt.Sprintf("(%d,%d,'%s','%s','%s')", c.ScdId, newid, inAreaIedName, "C", "T")) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 		} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+		//是否包含本体测控装置 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+		if strings.Contains(iedtypes, "CT#0") { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+			_, iedname := getIedByDesc(ieds, "CT", "本体") 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+			if len(iedname) > 0 { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+				for _, in := range iedname { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+					tmpIednameParts := scdParseMgr.ParseIedName(in) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+					if tmpIednameParts[6] == iednameParts[6] && tmpIednameParts[7] == iednameParts[7] { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+						insvalues = append(insvalues, fmt.Sprintf("(%d,%d,'%s','%s','%s')", c.ScdId, newid, in, "C", "T")) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+						break 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+					} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+				} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+			} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+		} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 		//智能终端(IB:开关\IT:分支\IF:分段)分高中低压侧 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 		h, m, l = c.getIedListByVol("IB", ieds, volMap) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 		h = append(h, m...) 
			 | 
		
	
	
		
			
				| 
					
				 | 
			
			
				@@ -1094,10 +1143,25 @@ func (c *CheckAreaMgr) pT(modelid int, iedtypes string, ieds map[string]orm.Para 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			lastChar := tmpIednameParts[7] 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			tmpVol := tmpIednameParts[3] + tmpIednameParts[4] 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			//高中低压电压等级相同的 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-			if (tmpVol == volMap["low"] || tmpVol == volMap["middle"] || tmpVol == volMap["hight"]) && (lastChar == "" || lastChar == iednameParts[7]) { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+			if (tmpVol == volMap["low"] || tmpVol == volMap["middle"] || tmpVol == volMap["hight"]) && tmpIednameParts[6] == iednameParts[6] && (lastChar == "" || lastChar == iednameParts[7]) { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 				insvalues = append(insvalues, fmt.Sprintf("(%d,%d,'%s','%s','%s')", c.ScdId, newid, inAreaIedName, "I", "B")) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 		} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+		//是否包含本体测控装置 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+		if strings.Contains(iedtypes, "IT#0") { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+			for n, row := range ieds { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+				if strings.HasPrefix(n, "IT") || strings.HasPrefix(n, "IB") || strings.HasPrefix(n, "IF") { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+					ieddesc := tools.IsEmpty(row["ied_desc"]) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+					if strings.Contains(ieddesc, "本体") { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+						tmpIednameParts := scdParseMgr.ParseIedName(n) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+						if tmpIednameParts[6] == iednameParts[6] && tmpIednameParts[7] == iednameParts[7] { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+							insvalues = append(insvalues, fmt.Sprintf("(%d,%d,'%s','%s','%s')", c.ScdId, newid, n, "I", "T")) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+							break 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+						} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+					} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+				} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+			} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+		} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 		h, m, l = c.getIedListByVol("IT", ieds, volMap) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 		h = append(h, m...) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 		h = append(h, l...) 
			 | 
		
	
	
		
			
				| 
					
				 | 
			
			
				@@ -1107,7 +1171,7 @@ func (c *CheckAreaMgr) pT(modelid int, iedtypes string, ieds map[string]orm.Para 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			lastChar := tmpIednameParts[7] 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			tmpVol := tmpIednameParts[3] + tmpIednameParts[4] 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			//高中低压电压等级相同的 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-			if (tmpVol == volMap["low"] || tmpVol == volMap["middle"] || tmpVol == volMap["hight"]) && (lastChar == "" || lastChar == iednameParts[7]) { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+			if (tmpVol == volMap["low"] || tmpVol == volMap["middle"] || tmpVol == volMap["hight"]) && tmpIednameParts[6] == iednameParts[6] && (lastChar == "" || lastChar == iednameParts[7]) { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 				insvalues = append(insvalues, fmt.Sprintf("(%d,%d,'%s','%s','%s')", c.ScdId, newid, inAreaIedName, "I", "T")) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 		} 
			 | 
		
	
	
		
			
				| 
					
				 | 
			
			
				@@ -1120,7 +1184,7 @@ func (c *CheckAreaMgr) pT(modelid int, iedtypes string, ieds map[string]orm.Para 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			lastChar := tmpIednameParts[7] 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			tmpVol := tmpIednameParts[3] + tmpIednameParts[4] 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			//高中低压电压等级相同的 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-			if (tmpVol == volMap["low"] || tmpVol == volMap["middle"] || tmpVol == volMap["hight"]) && (lastChar == "" || lastChar == iednameParts[7]) { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+			if (tmpVol == volMap["low"] || tmpVol == volMap["middle"] || tmpVol == volMap["hight"]) && tmpIednameParts[6] == iednameParts[6] && (lastChar == "" || lastChar == iednameParts[7]) { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 				insvalues = append(insvalues, fmt.Sprintf("(%d,%d,'%s','%s','%s')", c.ScdId, newid, inAreaIedName, "I", "F")) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 		} 
			 | 
		
	
	
		
			
				| 
					
				 | 
			
			
				@@ -1131,7 +1195,7 @@ func (c *CheckAreaMgr) pT(modelid int, iedtypes string, ieds map[string]orm.Para 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			inAreaIedName = tools.IsEmpty(r["ied_name"]) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			tmpIednameParts := scdParseMgr.ParseIedName(inAreaIedName) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			lastChar := tmpIednameParts[7] 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-			if lastChar == iednameParts[7] { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+			if tmpIednameParts[6] == iednameParts[6] && lastChar == iednameParts[7] { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 				insvalues = append(insvalues, fmt.Sprintf("(%d,%d,'%s','%s','%s')", c.ScdId, newid, inAreaIedName, "P", "M")) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 				//MM装置 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 				mmIedName := c.getMMName(tmpIednameParts, ieds, iednameParts[7]) 
			 | 
		
	
	
		
			
				| 
					
				 | 
			
			
				@@ -1144,7 +1208,7 @@ func (c *CheckAreaMgr) pT(modelid int, iedtypes string, ieds map[string]orm.Para 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			inAreaIedName = tools.IsEmpty(r["ied_name"]) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			tmpIednameParts := scdParseMgr.ParseIedName(inAreaIedName) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			lastChar := tmpIednameParts[7] 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-			if lastChar == "" || lastChar == iednameParts[7] { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+			if tmpIednameParts[6] == iednameParts[6] && (lastChar == "" || lastChar == iednameParts[7]) { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 				insvalues = append(insvalues, fmt.Sprintf("(%d,%d,'%s','%s','%s')", c.ScdId, newid, inAreaIedName, "P", "M")) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 				//MM装置 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 				mmIedName := c.getMMName(tmpIednameParts, ieds, iednameParts[7]) 
			 | 
		
	
	
		
			
				| 
					
				 | 
			
			
				@@ -1164,10 +1228,10 @@ func (c *CheckAreaMgr) pT(modelid int, iedtypes string, ieds map[string]orm.Para 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 //vol:电压等级 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 func (c *CheckAreaMgr) pL(modelid int, vol, iedtypes string, ieds map[string]orm.Params) { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 	scdParseMgr := new(ScdParse) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-	//scdNodeMgr := new(ScdNode) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+	scdNodeMgr := new(ScdNode) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 	db := orm.NewOrm() 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				  
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-	//scdXmlObject, _ := scdParseMgr.GetScdXmlObjectBySCDID(tools.IsEmpty(c.ScdId)) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+	scdXmlObj, _ := scdParseMgr.GetScdXmlObjectBySCDID(tools.IsEmpty(c.ScdId)) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 	for _, row := range ieds { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 		if tools.IsEmpty(row["vol"]) != vol || tools.IsEmpty(row["ied_type"]) != "P" || tools.IsEmpty(row["p_type"]) != "L" { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			continue 
			 | 
		
	
	
		
			
				| 
					
				 | 
			
			
				@@ -1176,6 +1240,7 @@ func (c *CheckAreaMgr) pL(modelid int, vol, iedtypes string, ieds map[string]orm 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 		mmIedName := "" 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 		pl_iedname := tools.IsEmpty(row["ied_name"]) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 		iednameParts := scdParseMgr.ParseIedName(pl_iedname) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+ 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 		//添加间隔数据 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 		dbdata := T_data_check_area{ 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			ModelId:  modelid, 
			 | 
		
	
	
		
			
				| 
					
				 | 
			
			
				@@ -1200,34 +1265,60 @@ func (c *CheckAreaMgr) pL(modelid int, vol, iedtypes string, ieds map[string]orm 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 				pmIedName = inAreaIedName 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 				if mmIedName == "" { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 					insvalues = append(insvalues, fmt.Sprintf("(%d,%d,'%s','%s','%s')", c.ScdId, newid, inAreaIedName, ty[0:1], ty[1:2])) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-					pmIedNameParts := scdParseMgr.ParseIedName(pmIedName) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+					//pmIedNameParts := scdParseMgr.ParseIedName(pmIedName) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 					//使用PM装置的名称去定义MM的名称 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 					ty = "MM" 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-					inAreaIedName = c.getMMName(pmIedNameParts, ieds, iednameParts[7]) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+					inAreaIedName = c.getMMName(iednameParts, ieds, iednameParts[7]) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 					mmIedName = inAreaIedName 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 				} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			} else if ty == "MM" { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 				if pmIedName != "" && mmIedName == "" { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-					pmIedNameParts := scdParseMgr.ParseIedName(pmIedName) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+					//pmIedNameParts := scdParseMgr.ParseIedName(pmIedName) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 					//使用PM装置的名称去定义MM的名称 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-					inAreaIedName = c.getMMName(pmIedNameParts, ieds, iednameParts[7]) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+					inAreaIedName = c.getMMName(iednameParts, ieds, iednameParts[7]) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 					mmIedName = inAreaIedName 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 				} else { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 					continue 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 				} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+			} else if ty == "PLC" || ty == "PCL" { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+				//判断是否是保测一体的 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+				if strings.Contains(iedtypes, "PLC") || strings.Contains(iedtypes, "PCL") { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+					no := []string{"PLC", "PCL", "PL"} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+					for _, n := range no { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+						plcIedName := n + iednameParts[3] + iednameParts[4] + iednameParts[5] + iednameParts[6] + iednameParts[7] 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+						if scdNodeMgr.GetIed(scdXmlObj, "", plcIedName) != nil { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+							inAreaIedName = plcIedName 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+							break 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+						} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+					} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+				} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			} else { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 				inAreaIedName = ty + iednameParts[3] + iednameParts[4] + iednameParts[5] + iednameParts[6] + iednameParts[7] 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+				if ty == "IML" { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+					//查找IML装置是否存在,不存在就查找MIL开头装置做中合智一体装置 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+					no := []string{"IML", "MIL"} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+					for _, n := range no { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+						milIedName := n + iednameParts[3] + iednameParts[4] + iednameParts[5] + iednameParts[6] + iednameParts[7] 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+						if scdNodeMgr.GetIed(scdXmlObj, "", milIedName) != nil { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+							inAreaIedName = milIedName 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+						} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+					} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+				} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			if strings.Index("ABCDE", iednameParts[7]) > -1 { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 				//最后一位是字母则说明是AB套 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 				switch ty { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 				case "CL": 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-					//测控装置,先判断是否分了AB套,没有标识(ied名称的最后一位是否是字母)则说明是多套共用装置 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-					clIedname := inAreaIedName + iednameParts[7] 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-					iedObj := ieds[inAreaIedName] 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-					if iedObj != nil { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-						//当前测控装置也分了AB套 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-						inAreaIedName = clIedname 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+					if strings.Contains(iedtypes, "PLC") || strings.Contains(iedtypes, "PCL") { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+						//不处理CL装置 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+					} else { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+						//测控装置,先判断是否分了AB套,没有标识(ied名称的最后一位是否是字母)则说明是多套共用装置 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+						clIedname := inAreaIedName + iednameParts[7] 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+						iedObj := ieds[inAreaIedName] 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+						if iedObj != nil { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+							//当前测控装置也分了AB套 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+							inAreaIedName = clIedname 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+						} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 					} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 					break 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 				default: 
			 | 
		
	
	
		
			
				| 
					
				 | 
			
			
				@@ -1243,8 +1334,8 @@ func (c *CheckAreaMgr) pL(modelid int, vol, iedtypes string, ieds map[string]orm 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 		} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 		//如果mm装置还未确定 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 		if mmIedName == "" { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-			pmIedNameParts := scdParseMgr.ParseIedName(pmIedName) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-			inAreaIedName := c.getMMName(pmIedNameParts, ieds, iednameParts[7]) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+			//pmIedNameParts := scdParseMgr.ParseIedName(pmIedName) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+			inAreaIedName := c.getMMName(iednameParts, ieds, iednameParts[7]) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			_, err = db.Raw(ins1 + fmt.Sprintf("(%d,%d,'%s','%s','%s')", c.ScdId, newid, inAreaIedName, "M", "M")).Exec() 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			if err != nil { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 				logger.Logger.Error(err) 
			 | 
		
	
	
		
			
				| 
					
				 | 
			
			
				@@ -1638,17 +1729,26 @@ func (c *CheckAreaMgr) cT(scdXmlObj *node_attr.SCL, scdNodeMgr *ScdNode, scdNode 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				  
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 //根据参考ied name找出应该关联PM装置 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 func (c *CheckAreaMgr) getPMName(iednameParts []string, ieds map[string]orm.Params) string { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-	tmpIedName := "PM" + iednameParts[3] + iednameParts[4] + iednameParts[5] + "1" + iednameParts[7] 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-	iedObj := ieds[tmpIedName] 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-	if iedObj != nil { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-	} else { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-		tmpIedName = "PM" + iednameParts[3] + iednameParts[4] + iednameParts[5] + "2" + iednameParts[7] 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-		iedObj = ieds[tmpIedName] 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+	//如果只有一个PM装置,则直接返回该 装置 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+	pmLst := []string{} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+	for n, _ := range ieds { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+		if strings.HasPrefix(n, "PM") { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+			pmLst = append(pmLst, n) 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+		} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+	} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+	if len(pmLst) == 1 { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+		return pmLst[0] 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+	} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+	//暴力匹配 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+	no := []string{"A", "B", "C", "D", "1", "2", "3", "4"} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+	for _, i := range no { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+		tmpIedName := "PM" + iednameParts[3] + iednameParts[4] + iednameParts[5] + i + iednameParts[7] 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+		iedObj := ieds[tmpIedName] 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 		if iedObj != nil { 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 			return tmpIedName 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 		} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 	} 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				-	return tmpIedName 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				+	return "" 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 } 
			 | 
		
	
		
			
				 | 
				 | 
			
			
				  
			 | 
		
	
		
			
				 | 
				 | 
			
			
				 //根据参考ied name找出应该关联MM装置 
			 |